Hemo 360

Hemo 360

Hemo 360 are used to count and identify blood cells at high speed and accuracy. Hemo 360 analyzers are used to conduct a complete blood count (CBC), which is usually the first test requested by physicians to determine a patients general health status. A complete blood count includes red blood cell (RBC), white blood cell (WBC), hemoglobin, and platelet counts, as well as hematocrit levels.

Hemo 360 5-part auto hematology analyzer uses Coulter’s Principle to find the size and volume of the cell. The sample is lysed and dissolved into an electrolyte solution in a container, which also holds a smaller container. The smaller container has 2 pumps running to and from its solution, one creating a vacuum and the other replacing the lost solution. The smaller container has a small hole (an orifice) near the bottom of the container. Coulter’s principle is applied through the use of two electrodes. One electrode (the internal electrode) is within the smaller container, and the other (the external electrode) is outside of the smaller container but within the electrolyte/sample solution. As the vacuum draws the sample cells through the orifice, the cell momentarily causes electrical resistance to the current as it passes through the orifice. This resistance is recorded, measured, amplified, and processed which can then be interpreted by the computer into a histogram. The 3-part analyzer is able to differentiate between 5 types of WBC’s, neutrophils, lymphocytes, and monocytes.

Technical Specification

Technology

  • 3-D Topographic Map
  • Integral Titanium Incubation System
  • Laser Scatter Technology
  • Flow Cytometry Technology
  • Cyanide Free Reagents
  • Autoloader & Close Tube
  • Random Direction Tube Barcode Scanning Technology(Optional)

Parameters

Regular Parameters:

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%

Research Parameters:

ALY#, ALY%, IG#, IG%

2 histograms, 2 scattergrams

Test Speed

Autoloader Mode: 60 Samples/hour

Close Tube Mode: 60 Samples/hour

Test Mode

CBC+5DIFF, CBC

Performance

Sample Volume

≤10ul

QC and Calibration

Multiple QC rules, including L-J, X-B etc.

Auto and manual calibration function for both whole blood mode and pre-diluted blood mode

Power Supply

100V-240V, 50Hz/60Hz

Sampling Mode

Autoloader: 50 tubes, Auto mixing, Random Direction Tube Barcode Scanning Technology

Close Tube: STAT Priority, Support both whole blood and capillary blood samples

Weight

75KG

Dimension

61cm(L)x76cm(W)x61cm(H)

Working Environment

  • Temperature: 10-30˚C
  • Humidity: 20-80%
  • Air pressure: 70-106KPa
  • Working Latitude: ≤3500m